The counterpart to the horizontal 19” PDU (Power Distribution Unit) – a PDU in a compact 1U size for installing vertically in the sides of server racks (ZeroU) The counterpart to the horizontal 19" PDU (Power Distribution Unit) – a PDU in a compact 1U size for installing vertically in the sides of server racks (ZeroU) and other applications in which IT devices are powered by country-specific outlets. The PDUs are reliable and durable thanks to their robust aluminium profile and high-quality components. Their modular design and the versatile function modules enable them to be set up to satisfy customised requirements. Furthermore, the high packing and power density ensure efficient power distribution.
Alternative versions with international outlets (C13/C19) are available on request.
16 A / 230 V
16 A / 230 V
Outlets in total
Phase(s)
Cable length
Plug
Current per phase (A)
Cable type
Miniature circuit breaker
Dimensions
16 A / 230 V
333.012216 A / 230 V
016 A / 230 V
116 A / 230 V
2 m16 A / 230 V
CEE 7/716 A / 230 V
16 A16 A / 230 V
H05VV-F 3G 1,50 mm²16 A / 230 V
16 A / 230 V
208 x 44 x 47 mm16 A / 230 V
333.41316 A / 230 V
016 A / 230 V
116 A / 230 V
2 m16 A / 230 V
CEE 7/716 A / 230 V
16 A16 A / 230 V
H05VV-F 3G 1,50 mm²16 A / 230 V
16 A / 230 V
565 x 44 x 47 mm16 A / 230 V
333.41716 A / 230 V
016 A / 230 V
116 A / 230 V
2 m16 A / 230 V
CEE 7/716 A / 230 V
16 A16 A / 230 V
H05VV-F 3G 1,50 mm²16 A / 230 V
16 A / 230 V
208 x 44 x 47 mm16 A / 230 V / With surge protection
16 A / 230 V / With surge protection
Outlets in total
Phase(s)
Cable length
Plug
Current per phase (A)
Cable type
Miniature circuit breaker
Dimensions
16 A / 230 V / With surge protection
800.233416 A / 230 V / With surge protection
016 A / 230 V / With surge protection
116 A / 230 V / With surge protection
2 m16 A / 230 V / With surge protection
CEE 7/716 A / 230 V / With surge protection
16 A16 A / 230 V / With surge protection
H05VV-F 3G 1,50 mm²16 A / 230 V / With surge protection
16 A / 230 V / With surge protection
608 x 44 x 47 mm16 A / 400 V
16 A / 400 V
Outlets in total
Phase(s)
Cable length
Plug
Current per phase (A)
Cable type
Miniature circuit breaker
Dimensions
16 A / 400 V
800.145316 A / 400 V
016 A / 400 V
316 A / 400 V
3 m16 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1713 x 44 x 47 mm16 A / 400 V
800.228316 A / 400 V
016 A / 400 V
316 A / 400 V
3 m16 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1457 x 44 x 47 mm16 A / 400 V
800.233716 A / 400 V
016 A / 400 V
316 A / 400 V
3 m16 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
734 x 44 x 47 mm16 A / 400 V
800.233916 A / 400 V
016 A / 400 V
316 A / 400 V
3 m16 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1203 x 44 x 47 mm16 A / 400 V
800.234216 A / 400 V
016 A / 400 V
316 A / 400 V
3 m16 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1458 x 44 x 47 mm16 A / 400 V
800.010716 A / 400 V
016 A / 400 V
316 A / 400 V
3 m16 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
821 x 44 x 47 mm16 A / 400 V
800.010916 A / 400 V
016 A / 400 V
316 A / 400 V
3 m16 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
821 x 44 x 47 mm16 A / 400 V
800.011316 A / 400 V
016 A / 400 V
316 A / 400 V
3 m16 A / 400 V
2 x WEF16 A / 400 V
16 A16 A / 400 V
H05VV-F 2 x 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1840 x 44 x 47 mm32 A/230 V/50 Hz
32 A/230 V/50 Hz
Outlets in total
Phase(s)
Cable length
Plug
Current per phase (A)
Cable type
Miniature circuit breaker
Dimensions
32 A/230 V/50 Hz
800.327132 A/230 V/50 Hz
032 A/230 V/50 Hz
132 A/230 V/50 Hz
0 m32 A/230 V/50 Hz
Connection terminal32 A/230 V/50 Hz
32 A32 A/230 V/50 Hz
32 A/230 V/50 Hz
32 A/230 V/50 Hz
930 x 44 x 44 mm32 A/230 V/50 Hz
800.327232 A/230 V/50 Hz
032 A/230 V/50 Hz
132 A/230 V/50 Hz
0 m32 A/230 V/50 Hz
Connection terminal32 A/230 V/50 Hz
32 A32 A/230 V/50 Hz
32 A/230 V/50 Hz
32 A/230 V/50 Hz
930 x 44 x 44 mm32 A/230 V/50 Hz
800.338432 A/230 V/50 Hz
032 A/230 V/50 Hz
132 A/230 V/50 Hz
0 m32 A/230 V/50 Hz
Connection terminal32 A/230 V/50 Hz
32 A32 A/230 V/50 Hz
32 A/230 V/50 Hz
32 A/230 V/50 Hz
955 x 44 x 44 mm32 A/230 V/50 Hz
800.338532 A/230 V/50 Hz
032 A/230 V/50 Hz
132 A/230 V/50 Hz
0 m32 A/230 V/50 Hz
Connection terminal32 A/230 V/50 Hz
32 A32 A/230 V/50 Hz
32 A/230 V/50 Hz
32 A/230 V/50 Hz
955 x 44 x 44 mm32 A / 400 V
32 A / 400 V
Outlets in total
Phase(s)
Cable length
Plug
Current per phase (A)
Cable type
Miniature circuit breaker
Dimensions
32 A / 400 V
800.234032 A / 400 V
032 A / 400 V
332 A / 400 V
3 m32 A / 400 V
CEE 32A32 A / 400 V
32 A32 A / 400 V
H05VV-F 5G 4,00 mm²32 A / 400 V
6 x C16A32 A / 400 V
1586 x 44 x 47 mmWith overvoltage protection | Mains and frequency filter
With overvoltage protection | Mains and frequency filter
Outlets in total
Phase(s)
Cable length
Plug
Current per phase (A)
Cable type
Miniature circuit breaker
Dimensions
With overvoltage protection | Mains and frequency filter
800.2631With overvoltage protection | Mains and frequency filter
0With overvoltage protection | Mains and frequency filter
1With overvoltage protection | Mains and frequency filter
3 mWith overvoltage protection | Mains and frequency filter
CCC 3-hole 16AWith overvoltage protection | Mains and frequency filter
10 AWith overvoltage protection | Mains and frequency filter
RVV 3G 1,50 mm²With overvoltage protection | Mains and frequency filter
With overvoltage protection | Mains and frequency filter
777 x 44 x 44 mmDo you need more information about our products and services? Please feel free to contact us.